REI CPM-700 Advanced professional portable sweep kit

Surveillance and High Security

Dear customers, please note that we will be closed Monday may 21, 2012 for Victoria day.
You are here:
+
+
+
+
+
+
+
+
-
+
+
+
+
+
+
+
+
+
+
+
+
+

REI CPM-700 Advanced professional portable sweep kit

SPT-CSS-014-ADV
Order by phone
1.888.779.8766
1.514.259.4884
2999.00$ CAD
 
Quantity
Buy
SPT-CSS-014-ADV
CLICK THE IMAGE TO ENLARGE

This unit is a broadband receiver designed to detect and locate all major types of electronic surveillance devices including room, phone, body bugs, audio and video transmitters, and tape recorders.

IMPORTANT NOTICE: Please note that the pruchase of this product requires an End User Certificate

This kit includes:

- CPM-700 Countersurveillance Probe/Monitor
- Standard RF Probe (50kHz-3GHz)
- Acoustic Leakage Probe
- Infrared Probe
- VLF Carrier Current Probe
- TVLF Patch Cable
- Magnetic Leakage Probe
- Auxiliary Patch Cable
- Modular Phone Adapter for network and phone line testing
- Tape Recorder Patch Cords
- Soft Carrying Case

Acoustic Leakage Probe
Frequency Response50 Hz - 10 kHz (surface dependent)
Audio Amplifier
AGC Dynamic Range100 dB (High and Low Gain)
Frequency Response100 Hz - 15 kHz +3 dB (filtered) 500 Hz -24 dB/octave, 2.5 kHz -18 dB/octave
Headphone Output5 V p-p (peak-to-peak), 220 Ω nominal
Input Impedance50 kΩ balanced
Input Range1.7 μV - 10 V (135 dB)
Record Out25mV p-p nominal with AGC
Display
Alert Output2.8kHz tone or silent red LED at 2Hz
Internal LCD screen 18 segment with pulsing single segment trip point 50dB dynamic range (1 segment High Gain to MAX Low Gain)
Remote OutputN.O. contact (300mA 25V MAX)
General Specifications
Wideband Coverage 200Hz to over 3GHz with no gaps
Infrared Probe
Frequency Response10 kHz - 5 MHz
Viewing Angle± 40 deg
Wavelenght725 - 1150 nm
Physical Specifications
DimensionsCPM-700 Unit: 9 1/8 x 6 1/8 x 1 3/4 in, 23.2 x 15.6 x 4.4 cm
WeightCPM-700 Unit: 39 oz, 1.1 kg
Power
Battery8 ea. MN1500 AA Alkaline - Life 10-16 hrs
InputAC Adapter/ Charger: 95-l30VAC 50-60Hz, ou 200-275VAC 50-60Hz
Low battery indicator Low Battery Indicator: approx. 10% remaining power
Output12VDC with 500mA NiCad Recharge Time: 8-10 hrs
RF Probe
Gain20dB nominal Frequency
Response 50kHz-2GHz ±3dB 3GHz-10dB 2GHz - 12 GHz (Microwaves)
Sensitivity-62dBm (1 segment) -85dBm M.D.L.
VLF Probe
Frequency Response15kHz-1MHz-3dB
Isolation1500 VAC 60Hz
MAX input voltage300 VAC 50-60Hz
Sensitivity-38dBm (1 segment) -60 M.D.L.
Have any questions?    Consult the Questions / Answers section on our Forum